ACME INDUSTRIES - INCIDENT REPORT Date: April 12, 2026 Ref: INC-2026-0412-07 Classification: INTERNAL - STAFF CONFIDENTIAL SUMMARY At 02:47 UTC a cooling-loop pressure sensor on Line 3 tripped, causing an automatic shutdown of Compressor C-14. The event lasted 23 minutes. No injuries were reported. Production loss estimated at 4.2 metric tons. ON-SITE RESPONDERS Lead Engineer: Marcus Chen, [EMAIL REDACTED], [PHONE REDACTED]Shift Supervisor: Priya Kapoor, [EMAIL REDACTED], [PHONE REDACTED]Safety Officer: David Okonkwo, [EMAIL REDACTED], [PHONE REDACTED]Maintenance Tech: Sofia Reyes, [EMAIL REDACTED], [PHONE REDACTED]TIMELINE 02:47 Pressure sensor PS-314 exceeded 185 bar threshold (limit: 180 bar). 02:48 Automated shutdown sequence initiated for Compressor C-14. 02:51 Marcus Chen ([EMAIL REDACTED]) arrived on scene. 02:55 Root cause identified: fouled check valve CV-88 on return loop. 03:02 Priya Kapoor ([EMAIL REDACTED]) authorized manual bypass. 03:10 Replacement valve installed by maintenance crew. 03:10 System pressure normalized at 162 bar. Compressor C-14 restarted. ROOT CAUSE Check valve CV-88 accumulated calcium carbonate scale over approx. 6 weeks, restricting flow and causing upstream pressure to exceed trip threshold. Valve was last inspected 2026-02-28 and was within tolerance at that time. CORRECTIVE ACTIONS 1. Replace all check valves on Line 3 return loop (CV-85 through CV-92). Owner: Marcus Chen ([EMAIL REDACTED]), Due: 2026-04-19 2. Reduce inspection interval from 8 weeks to 4 weeks for cooling-loop valves. Owner: Priya Kapoor ([EMAIL REDACTED]), Due: 2026-04-14 3. Install inline water-quality monitor on cooling supply header. Owner: David Okonkwo ([PHONE REDACTED]), Due: 2026-05-01 DISTRIBUTION Plant Manager: [EMAIL REDACTED] Regional EHS: [EMAIL REDACTED] Insurance Liaison: [EMAIL REDACTED], [PHONE REDACTED]END OF REPORT For Evaluation Purposes Only